Mfg Part Number: 11-00091-001 | Alternate P/N: 1100091001 | Manufacturer: General Dynamics Ots Inc |
NSN : 5950-01-324-1131 | NIIN : 013241131 | Item Name : transformer power |
CAGE Code : 21562 | FSC : 5950 Coils and Transformers |
Thank you for your interest in the 11-00091-001 part of Transformer Power, we have in stock on Integrated NSN. This particular General Dynamics Ots Inc item is listed alongside the NSN 5950-01-324-1131 and part number 11-00091-001 for your ease of search. With current availability for this item, we encourage you to take advantage of our Instant RFQ service in order to acquire a competitive quote for your comparisons. As our team members can be contacted 24/7x365, responses to requests or inquiries are completed with haste.
Take your time to explore our listing of part numbers like 11-00091-001 and you will find that the NSN 5950-01-324-1131 can be found listed under FSC 5950 Coils and Transformers and CAGE Code 21562. However, we carry a myriad of other NSN parts, all of which have been sourced from reputable distributors like General Dynamics Ots Inc. Kickoff the procurement process with a quote request that includes all of your part requirements and see how Integrated NSN can serve as your go-to sourcing solution. For additional questions, call or email us directly; we are ready to help you meet your operational deadlines however necessary.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-324-1131 Item Description: Transformer Power | 5950 | 013241131 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
11-00091-001 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.896 INCHES MINIMUM AND 0.916 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.896 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.916 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.242 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.262 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AFHM | MOUNTING TAB WIDTH | 0.002 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 160.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 630.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.6 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 45.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 7.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 93.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 72.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 16340-11-00091 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN |
CRBZ | WINDING OPERATING CURRENT | 630.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 134.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ABMK | OVERALL WIDTH | 0.896 INCHES MINIMUM AND 0.916 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | TAB SINGLE GROUP |
CRMJ | WINDING POWER RATING | 214.4 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 18.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND FIVE SECONDARY WINDINGS |
ABKW | OVERALL HEIGHT | 1.290 INCHES MINIMUM AND 1.330 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.6 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |